PRODUKSI DAN PERANCANGAN


Mesin Bubut

Minggu, 03 Januari 2010

Purging of Boiler Circulating Water Pump

1.5 Purging of Boiler Circulating Water Pump
1. Verify closed cooling water is aligned to boiler circulating water pumps prior to filling:
a) Closed cooling water supply valve SG03-9 (21) open
b) Closed cooling water control valve inlet isolation valve SG03-11 (22) open
c) Closed cooling water control valve SG03-1 (66) in Auto
d) Bypass SG03-216 closed
e) Emergency thermal barrier cooling valve SG03-2 closed
2. Verify boiler circulating pump thermal barrier valves are locked open:
a) Boiler circulating pump 11/21
i) Thermal barrier supply valve SG03-20
ii) Thermal barrier return valve SG03-28 (16)
b) Boiler circulating pump 12/22
i) Thermal barrier supply valve SG03-21
ii) Thermal barrier return valve SG03-29 (16)
c) Boiler circulating pump 13/23
i) Thermal barrier supply valve SG03-22
ii) Thermal barrier return valve SG03-30 (16)
d) Boiler circulating pump 14/24
i) Thermal barrier supply valve SG03-23
ii) Thermal barrier return valve SG03-31 (16)
3. Verify boiler circulating pumps closed cooling water return header is aligned as follows:
a) Closed cooling water return control valve inlet isolation valve SG03-15 (62) is open
b) Closed cooling water return control valve inlet SG03-3 (67) in Auto
c) Closed cooling water return control valve outlet isolation valve SG03-17 (62) is open
d) Bypass SG03-217 closed
e) Emergency thermal cooling drain SG03-4 closed (vlv 14 open)
4. Close or Verify Closed boiler circulating pump suction valve as appropriate:
a) Boiler circulating pump 11/21 suction valve SG03-5 (2)
b) Boiler circulating pump 12/22 suction valve SG03-6 (2)
c) Boiler circulating pump 13/23 suction valve SG03-7 (2)
d) Boiler circulating pump 14/24 suction valve SG03-8 (2)
5. Close or Verify Closed boiler circulating pump discharge valve as appropriate:
a) Boiler circulating pump 11/21 discharge valves SG03-126 (3), and SG03-127 (3)
b) Boiler circulating pump 12/22 discharge valves SG03-128 (3), and SG03-129 (3)
c) Boiler circulating pump 13/23 discharge valves SG03-130 (3), and SG03-131 (3)
d) Boiler circulating pump 14/24 discharge valves SG03-132 (3), and SG03-133 (3)
6. Close boiler water circulating pump bypass valves as appropriate:
a) Boiler circulating pump 11/21 bypass valves SG03-94 (5), and SG03-106 (6)
b) Boiler circulating pump 12/22 bypass valves SG03-95 (5), and SG03-108 (6)
c) Boiler circulating pump 13/23 bypass valves SG03-96 (5), and SG03-110 (6)
d) Boiler circulating pump 14/24 bypass valves SG03-97 (5), and SG03-112 (6)
7. Open drain valves (44) and (18).
8. Verify Closed Strainer drain valves SG03-44, and SG03-45.
9. Close boiler circulating pump motor cavity isolation valve:
a) Boiler circulating pump 11/21 motor cavity valve SG03-246 (10A)
b) Boiler circulating pump 12/22 motor cavity valve SG03-247 (10A)
c) Boiler circulating pump 13/23 motor cavity valve SG03-248 (10A)
d) Boiler circulating pump 14/24 motor cavity valve SG03-249 (10A)
10. Close boiler circulating pump motor cavity cooling water valve:
a) Boiler circulating pump 11/21 motor cavity cooling water SG03-250
b) Boiler circulating pump 12/22 motor cavity cooling water SG03-251
c) Boiler circulating pump 13/23 motor cavity cooling water SG03-252
d) Boiler circulating pump 14/24 motor cavity cooling water SG03-253
11. Open bypass valves and vent valves:
a) SG03-102 (5A), SG03-107 (6A), (7), and (57)
b) SG03-103 (5A), SG03-109 (6A), (7), and (57)
c) SG03-103 (5A), SG03-111 (6A), (7), and (57)
d) SG03-104 (5A), SG03-113 (6A), (7), and (57)
12. Verify low pressure fill spool piece is removed and outlet isolation valve SG03-39 (50) is closed.
13. Open boiler circulating pumps high pressure fill isolation valve SG03-36 (38).
14. Open boiler circulating pumps fill strainer inlet (SG03-42) isolation valve.
15. Blowdown fill line through fill strainer drain valves SG03-44, and SG03-45.
16. Open boiler circulating pumps fill outlet (SG03-43) isolation valves.

2 komentar: